- MODEL : DY-300
- Measuring Method : Digital Measuring System by Micom (WATER & Waterless select measurement)
- Air Pressure sensor : Ceramic pressure cell Max 200.0 kPa,¡¾0.1 kPa
- Air Content Measuring Range : 0.0 % ~ 9.9 % (20 ¡É ¡¾0.1%)
0.00 % ~ 9.99 % (20 ¡É ¡¾0.01%)
- Unit Mass Inference Method : Tight, Simple Method of unit mass inference method by Air Meter Method in Civil Laboratory
- Operating Temp/Humidity : 0.0 ¡É ~ 50.0 ¡É / 80 % RH (Relative Humidity)
- Temperature Compensation : ATC (can select existence nonexistence)
- Memory : Memory recalling holds 30 Readings
- Display : Graphic Dot LCD (128*64)
- Communication : IR Infrared Ray
(9600 bps, 8Data Bit, No Parity, 1Stop Bit)
- Power Supply : Adapter,Rechargable: DC12V / 500mA
- Option : Printer (Data output)